free web stats
Home Products Solutions For LC

Adrona Water Purification Units

Adrona Water Purification Units

adrona logo

1.    Crystal B series:

Crystal B ultrapure systems are multi-purpose water purification systems. The Crystal B systems produce ultrapure and pure water directly from tap water.

 Features:

  • Tank filling control
  • Tap water pressure control
  • Protection from tank sensor failure
  • The Crystal B systems include:
    • Boost pump
    • Pre-filter set
    • Reverse osmosis module
    • Deionization module
    • Final stage polishing module
    • 25L storage tank with an integrated Grade II dispensing pump
    • Recirculation system
    • Point-of-use final filter (0.22 μm microfilter for the Crystal B Trace and HPLC systems)
    • Ultrafilter for the Crystal B Bio systems; and/or a photo-oxidation module for elimination of organics (HPLC and Bio configurations)
    • UV sterilization module (Bio configuration)

 

Models:

  • Crystal B Trace
  • Crystal B Bio
  • Crystal B HPLC

 

2.     Integrity Series

Crystal Integrity systems produce ultrapure water directly from tap water. Ultrapure water produced by the Crystal Integrity system, complies with the requirements for Grade 1 water in accordance with relevant standards (ISO 3696, ASTM, CLSI).The Crystal Integrity systems are recommended for laboratories with relatively low consumption of ultrapure water (about 5 liters per day).

Features:

  • Used in
    • Inorganic trace analysis
    • Liquid chromatography
    • Cell culture
    • Molecular biology
  • Space-saving, integrated, 5L tank is made of high density polyethylene to minimize contamination
  • All Integrity systems have a controller with a graphic LCD display for water quality indication.
  • Bluetooth Option Available
  • Tank filling control
  • Tap water pressure control

 

Models:

  • Integrity HPLC system
  • Integrity Bio system

 

3.    Onsite Series

Adrona Onsite systems produce ultrapure water from pre-treated water. Ultrapure water produced by the Adrona Onsite complies with the requirements for Grade 1 water for all relevant standards (ISO 3696, ASTM, CLSI). Adrona Onsite systems are recommended for laboratories with consumption of ultrapure water of 5-10 litres per day.

Features:

  • Used in:
    • Inorganic trace analysis
    • Liquid chromatography
    • Cell culture
    • Molecular biology
  • Integrated Storage tank
  • The Crystal Onsite system comes with a 5L carboy. The carboy has a stopcock and handle for convenient transportation of water from a water still to the Crystal Onsite unit.
  • Graphic LCD Display
  • Bluetooth option Available
  • Tank filling Control

Models:

  • Onsite HPLC System
  • Onsite Bio System

 

4.    Crystal B Pure Series

The Crystal B Pure systems produce purified water for general laboratory applications and analytical inorganic methods. Crystal B Pure water complies with the requirements of ISO 3696 Grade 2. The costs of pure water production are lower in comparison to the costs of ultrapure water.

Features:

  • Used in:
    • Many inorganic methods of analysis (e. g. flame spectrometry)
    • Wet chemistry methods
    • Electrochemistry
    • Labware washing, etc
  • Boost pump
  • Pre-filter set
  • Reverse osmosis module
  • Deionization module

 

5.    Crystal E Series

The Crystal E ultrapure systems are economy class, multi-purpose, water purification systems

Features:

  • Boost pump
  • Pre-filter
  • RO module
  • Deionization module
  • Polishing module
  • 25L storage tank with integrated Grade 2 dispensing pump
  • Recirculation system
  • Point-of-use Final Filter:
    • 0.22 μm microfilter for Crystal E Trace and HPLC systems
    • Ultrafilter for Crystal E Bio systems
  • Photo-oxidation module for reduction of organics (for HPLC and Bio configurations)
  • UV sterilization module (for the Bio configuration)

Models:

  • Crystal E Trace System
  • Crystal E HPLC System
  • Crystal E Bio System

 

6.    Crystal E Pure and RO Systems

Crystal E RO and Pure systems produce purified water of ISO 3696 Grade 3 (RO) and ISO 3696 Grade2 (Pure). Pure and RO water have much lower production costs than ultrapure (Grade 1) water. The Crystal E RO system reduces contamination in water by more than 98%. The conductivity of Crystal E RO purified water is typically less than 5 μS/cm (dependent upon feed water). The Crystal E Pure system produces water that is essentially free from inorganic contamination, and low in TOC content.

Features:

  • Used in:
    • Many inorganic methods of analysis (e. g. flame spectrophotometry)
    • Wet chemistry methods
    • Electrochemistry
  • Labware washing, etc.
  • Boost pump
  • Pre-filter
  • Reverse osmosis module
  • Deionization module (for Pure systems only)
  • A UV-sterilization module is available as an option

 

7.    Crystal 7 RO and Pure Series

The Crystal 7 Pure system (P/N C7-1001) is an entry level water purification system with very low system running costs. It is wall-mounted and does not require any space on a laboratory bench. The Crystal 7 Pure system produces purified water for general laboratory applications and analytical methods

Features:

  • Used in:
    • Many inorganic methods of analysis (e. g. flame spectrophotometry)
    • Wet chemistry methods
    • Electrochemistry
    •  Labware washing, etc
  • The Crystal 7 RO system (P/N C7-1241) produces water that complies with ISO 3696 Grade 3 requirements
  • Graphic LCD display providing system status info and water quality monitoring readouts
  • Tank filling control
  • Tap water pressure control
  • Protection from tank sensor failure
  • Boost pump
  • Pre-filter set
  • Reverse osmosis module
  • Deionization module
  • A UV-sterilization module is available as an option

 

8.    Sterifeed

Sterifeed is a water purification system that is designed to produce feed water for autoclaves. The Sterifeed system produces water with conductivity of 5-11 uS/cm. This is within the recommended conductivity range of 3-15 uS/cm, presented by autoclave manufacturers.

Features:

  • Pressurized water storage tank provides a consistent water supply to the autoclave.
  • LCD display that provides information about the system status, water quality, and the remaining pre-filter life
  • The Sterifeed comes with the necessary accessories for connection to an autoclave, and no tools are required

 

9.    Crystal Clinic

The Crystal Clinic water purification system is designed to provide purified water to automated biochemistry analyzers.

Features:

  • Pressure Regulator
  • Large LCD display provides information about the system status, water quality, and pre-filter life.

Copyright © 2024 Chromatopak. All rights reserved.
Website Design by Ink my web