General Separations Capillary Columns
General Separation Technologies, USA offers a wide selection of high quality GsBP series of GC Capillary Columns.
Features:
- Consistent high performance w.r.t inertness and column bleed
- Generates high efficiency separations
- Stringent Q.C methods adopted
- Wide range of polysiloxane based stationary phases
- Wide selection of PLOT columns
GsBP -1, 100% poly (dimethylsiloxane)
- 100% bonded and crosslinked dimethylpolysiloxane
- Non-polar, equivalent to USP phase G2
- Solvent rinseable and high temperature limit
- Wide range of coloumn dimensions and stationary phase film thickness
- Low column bleed, inert surface and high efficiency
- Most popular for general applications
- Similar to : DB-1,BP-1, CP-Sil5CB, RTX-1, ZB-1, AT-1, HP-1, SPB-1
GsBP-1 MS, 100% poly(dimethylsiloxane)
- Identical selectivity to GsBP-1 but with much lower column bleed
- Ideal for GC-MS analysis and first choice for new method development
- Similar to DB-1MS,BP-1, CP-Sil5CB Low bleed, RTX-1MS
GsBP -5, 5% phenyl, 95% dimethyl polysiloxane
- 5% phenyl, 95% dimethyl polysiloxane bonded and crosslinked
- Non-polar, equivalent to USP phase G27
- Solvent rinseable and high temperature limit
- Wide range of column dimensions and stationary phase film thickness
- Low column bleed, inert, neutral surface with high efficiency
- Most popular for general applications
- Similar to DB-5,BP-5, CP-Sil8CB, RTX-5, ZB-5, AT-5, HP-5, SPB-5
GsBP-5 MS, 5% phenyl, 95% dimethyl polysiloxane
- Identical selectivity to GsBP-5 but which much lower column bleed
- Best surface inertness for wide range of compounds
- Ideal for GC-MS analysis or for new method development
- Similar to : to DB-5MS,BPX-5, CP-Sil8CB Low bleed, RTX-5MS, AT-5MS
GsBP- 35 MS, 35% phenyl, 65% dimethyl polysiloxane
- Bonded and crosslinked 35% phenyl , 65% dimethylsiloxane phase
- Equivalent to USP phase G-42
- Inert to many active compounds
- Low column bleed to improve sensitivity and quantitation
- Applications: Aroclors, PCBs, amines, pesticides, pharmaceutical molecules
- Good confirmation analysis of active compounds on GsBP-5MS columns
- Similar to : DB-35MS, BPX-35
GsBP -50 +MS, 50% phenyl, 50% dimethyl polysiloxane
- Boonded and crosslinked 50% phenyl, 50% dimethyl polysiloxane
- Equivalent to USP phase G3
- Inert to many active compounds
- Low column bleed to improve sensitivity and quantitation
- Applications: common drug screens, phenols, PAHs, free steroids, pesticides, herbicides.
- Good confirmation of the analysis of active compounds on GsBP-5MS or GsBP-35MS columns.
- Similar to : DB-17MS, BPX- 50, RTX-50, SPB-50, AT-50
GsBP-1701, 14% cyanopropylphenyl, 86% dimethyl polysiloxane
- Bonded crosslinked cyanopropylphenyl, 86% dimethyl polysiloxane phase
- Low to mid polarity
- Equivalent to USP phase G-46
- Inert to many active compounds
- Applications: pesticides, herbicides, halogenates
- Good confirmation of analysis of active compounds on GsBP-5MS or GsBP-50+ MS columns
- Similar to DB -1701, BP- 10, CP Sil9CB, SPB-1701, ZB-1701
GsBP-1301, 6% cyanopropylphenyl, 94% dimethyl polysiloxane
- Bonded and crosslinked 6% cyanopropylphenyl, 94% dimethyl polysiloxane phase
- Equivalent to USP phase G 43, low to mid polarity
- Inert to many active compounds
- Applications: pesticides, herbicides, halogenates.
- Good confirmation of the analysis of active compounds on GsBP- 5MS or GsBP -35MS columns
- Similar to DB – 1301, RTX – 1301
GsBP- 624 proprietary polysiloxane stationary phase
- Bonded and crosslinked specially designed stationary phase for EPA methods
- Low Polarity
- Equivalent to USP phase G43 6% cyanopropylphenyl, 94% methyl polysiloxane
- Inert to many active compounds
- Applications: EPA methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260
- Similar to : DB-624, BP-624, RTX-624, ZB-624
GsBP INOWAX, Bonded polyethylene glycol
- Bonded and crosslinked PEG
- Solvent rinseable
- Highest temperature limits of bonded PEG phases
- Polar phase, equivalent to USP phase G 16
- Wide applications of polar solvent analysis in food, pharma, cosmetics, petrochemical industries.
- Similar to : DB-WAX, HP-Innowax, BP-20, CP-WAX52CB, Supelcowax-10, Stabilwax, ZB-WAX
GsBP- CarboWax 20M polyethylene glycol
- PEG, MW 20,000
- Non-bonded non- crosslinked phase
- Polar phase equivalent to USP phase G16
- Replacement of packed columns with CArbowax 20M modified
GsBP – FFAP, bonded acid modified PEG
- Nitrorerepthalic acid modified PEG
- Bonded and crosslinked
- Non-alcohol/aqueous solvent rinseable
- High temperature limit
- Polar phase, equivalent to USP phase G35
- Designed for the analysis of volatile fatty acids and phenols
- Similar to : DB-FFAP, Stabilwax-DA, CP-Wax58CB
GsBP PONA 100% dimethylpolysiloxane
- Bonded and crosslinked
- High resolution Analysis of hydrocarbons
- Specifically configured for analysis of Petroleum processed products(PONA, PIANO etc)
- Similar to HP-PONA, Petrocol DH, DB-Petro 100
GsBP- 502.2, proprietary phase
- Bonded and cross linked
- Excellent peak shapes for Volatile Organic Compounds
GsBP-PLOT Al2 O3 “KCL”
- Least selective Olefins (“polar”) aluminium oxide phase
- Deactivated with KCL
- Good baseline separation of most C1 to C10 hydrocarbons
- Olefins may co-elute with corresponding paraffin over C5
- Minimum surface adsorption of dienes and halocarbons
- ASTM recommended phase
- Preferred choice for hydrocarbon separation
- Similar to : GS-Alumina KCL, CP-Al2O3/KCL, RT-AluminaPLOT
GsBP-PLOT Al2 O3 “S”
- Good selective Olefins (mid “polar”) aluminium oxide phase
- Deactivated with Na2SO4 salt
- Excellent baseline separation of C1 to C10 hydrocarbons, excellent of C3, C4 misomer baseline separation
- Less accurate quantitations of dienes and halocarbons
- ASTM recommended phase
- Preferred choice for hydrocarbon separation
- Similar to : HP-PLOT Al2O3’S’, CP-Al2O3 PLOT Na2SO4
GsBP-PLOT Al2O3 “M”
- Strong selective Olefins (most “polar”) aluminium oxide phase
- Deactivated with Na2MoO4 salt
- Mostly baseline separation of C1 to C10 hydrocarbons, good baseline separation of cyclopropane from propylene
- Accurate quantitations of dienes and halocarbons
- ASTM recommended phase
- Preferred choice for hydrocarbon separation
- Similar to : HP-PLOT Al2O3M
GsBP-PLOT MoleSieve, molecular sieves, 5A type
- Molecular Sieve, Zeolite, 5A
- Thin and thick coatings for push limit separations, e.g. Ar/O2 separation at 35°C, O2 /N2 within 15sec
- Truly immobilize coating and smooth baseline workable for valve switching
- Preferred column to analyze fixed gases from hydrocarbon streams
- Elution order, H2 , He, Ne, O2 , N2, CH4 , CO
- Regeneration of performance from water/CO2 adsorptions at 250°C for 3hr
- ASTM recommended phase
- Noble gas, air from methane, fuel gas, etc
- Often used with other PLOT columns for fixed gas separation from sample matrix
- Similar to : HP-PLOT MoleSieve., CP-Moleseive 5A
GsBP-PLOT GasPro, proprietary porous silica coating
- Proprietary Silica base phase
- Very inert to wide range of gases including sulfur gases and Freons, symmetric peak shapes
- Truly immobilized coating and smooth baseline workable for valve switching
- Preferred column to analyze sulfur gases from hydrocarbon streams and air
- Separation of CO and CO2
- Minimum effect of water on retention time
- Regeneration of performance from water adsorptions at 250C for 3hr
- ASTM recommended phase
- GC-MS applicable
- Similar to : GS-Gas Pro, CP-Silica PLOT
GsBP-PLOT Q, porous divinylbenzene polymer
- Divinylbenzene polymer particle, nonpolar, close to traditional PoraPak Q
- Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures
- Highest temperature limit, upto 280/300°C
- Baseline separation of Air, CO2 , water, sulfur gases, hydrogen chlorine, ammonia/light amines from hydrocarbons such as refinery stream, natural gas, and engine exhaust
- Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons
- Excellent inertness and stability of water/alcohol sample, a good secondary choice of wax column for alcohol analysis
- Excellent tolerance to strong acid/base sample without affecting retention time
- Good anti-oxidation at 280°C and fast regeneration of performance
- Observed slight sulfur gas, hydrogen chlorine, and amine absorption
- Water peak is tailing, but no effect on retention
- Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or Organic solutions
- Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection
- Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refinery Gas, dienes, ethylene, propylene
- Similar to : HP-PLOT Q, CP-PoraPLOT Q, RT-Q PLOT
GsBP-PLOT U, porous ethylene glycol dimethacrylate copolymer
- Divinylbenzene and Ethylene glycol dimethacrylate copolymer particle, polar
- Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures
- Improved separation and selectivity of Air, CO2 , water, sulfur gases, hydrogen chlorine, ammonia/light amines from hydrocarbons
- Symmetric water peak shape, water elute after C3
- Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons
- Excellent inertness and stability of water/alcohol sample, a good secondary choice of wax column for alcohol analysis
- Excellent tolerance to strong acid/base sample without affecting retention time
- Observed slight sulfur gas, hydrogen chlorine, and amine absorption
- Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or organic solutions
- Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection
- Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refinery gas, Dienes, ethylene, propylene
- Similar to : PoraPLOT U, RT-U PLOT
GsBP-Blood Alcohol Column, proprietary PLOT phase
- Proprietary PLOT phase
- Reliable blood alcohol analysis
- Tolerance of direct sample injection
- Excellent confirmation column against other blood alcohol columns using t-butanol as internal standard
- Similar to : DB-ALC1, RTX-BAC1